Changes

From Opengenome.net

FACS

17,385 bytes added, 12:20, 9 March 2008
no edit summary
<p><strong>Flow cytometry</strong>is a technique for counting, examining, and sorting microscopic particles suspended in a stream of fluid. It allows simultaneous <a href="/wiki/Parametric_model" title="Parametric model">multiparametric</a> analysis of the physical and/or <a href="/wiki/Chemical" title="Chemical" class="mw-redirect">chemical</a> characteristics of single cells flowing through an <a href="/wiki/Optical" title="Optical" class="mw-redirect">optical</a> and/or electronic detection apparatus.</p><table summary="Contents" id="toc" class="toc"> <tbody> <tr> <td><br /> </td> </tr> </tbody></table><script type="text/javascript">//<![CDATA[ if (window.showTocToggle) { var tocShowText = "show"; var tocHideText = "hide"; showTocToggle(); } //]]></script><p><a name="Principle" id="Principle"></a></p><h2><span class="editsection"></span><span class="mw-headline">Principle</span></h2><p>A beam of <a href="/wiki/Light" title="Light">light</a> (usually <a href="/wiki/Laser" title="Laser">laser</a> light) of a single wavelength is directed onto a <a href="/wiki/Hydrodynamic_focusing" title="Hydrodynamic focusing">hydro-dynamically focused</a> stream of fluid. A number of detectors are aimed at the point where the stream passes through the light beam; one in line with the light beam (Forward Scatter or FSC) and several perpendicular to it (Side Scatter (SSC) and one or more <a href="/wiki/Fluorescent" title="Fluorescent" class="mw-redirect">fluorescent</a> detectors). Each suspended particle passing through the beam scatters the light in some way, and fluorescent chemicals found in the particle or attached to the particle may be excited into emitting light at a lower frequency than the light source. This combination of <a href="/wiki/Scattering" title="Scattering">scattered</a> and <a href="/wiki/Fluorescent" title="Fluorescent" class="mw-redirect">fluorescent</a> light is picked up by the detectors, and by analysing fluctuations in brightness at each detector (one for each <a href="/wiki/Emission_spectrum_%28fluorescence_spectroscopy%29" title="Emission spectrum (fluorescence spectroscopy)" class="mw-redirect">fluorescent emission peak</a>) it is then possible to extrapolate various types of information about the physical and chemical structure of each individual particle. FSC correlates with the <a href="/wiki/Cell_%28biology%29" title="Cell (biology)">cell</a> volume and SSC depends on the inner complexity of the particle (i.e. shape of the <a href="/wiki/Cell_nucleus" title="Cell nucleus">nucleus</a>, the amount and type of <a href="/wiki/Cytoplasm" title="Cytoplasm">cytoplasmic</a> granules or the <a href="/wiki/Cell_membrane" title="Cell membrane">membrane</a> roughness). Some flow cytometers on the market have eliminated the need for fluorescence and use only light scatter for measurement. Other flow cytometers form images of each cell's fluorescence, scattered light, and transmitted light.</p><p><a name="Flow_cytometers" id="Flow_cytometers"></a></p><h2><span class="editsection"></span><span class="mw-headline">Flow cytometers</span></h2><p>Modern flow cytometers are able to analyse several thousand particles every second, in &quot;real time&quot;, and can actively separate and isolate particles having specified properties. A flow cytometer is similar to a <a href="/wiki/Microscope" title="Microscope">microscope</a>, except that instead of producing an image of the cell, flow cytometry offers &quot;high-throughput&quot; (for a large number of cells) automated <a href="/wiki/Quantification" title="Quantification">quantification</a> of set parameters. To analyze solid <a href="/wiki/Biological_tissue" title="Biological tissue" class="mw-redirect">tissues</a> single-cell suspension must first be prepared.</p><p>A flow cytometer has 5 main components:</p><ul> <li>a flow cell - liquid stream (sheath fluid) carries and aligns the cells so that they pass single file through the light beam for sensing. </li> <li>a light source - commonly used are lamps (<a href="/wiki/Mercury_%28element%29" title="Mercury (element)">mercury</a>, <a href="/wiki/Xenon" title="Xenon">xenon</a>); high power water-cooled lasers (<a href="/wiki/Argon_laser" title="Argon laser" class="mw-redirect">argon</a>, <a href="/wiki/Krypton_laser" title="Krypton laser" class="mw-redirect">krypton</a>, dye laser); low power air-cooled lasers (argon (488nm), red-HeNe (633nm), green-HeNe, HeCd (UV)); <a href="/wiki/Diode_laser" title="Diode laser" class="mw-redirect">diode lasers</a> (blue, green, red, violet). </li> <li>a detector and Analogue to Digital Conversion (ADC) system - generating FSC and SSC as well as fluorescence signals. </li> <li>an amplification system - <a href="/wiki/Linear" title="Linear">linear</a> or <a href="/wiki/Logarithmic_scale" title="Logarithmic scale">logarithmic</a>. </li> <li>a computer for analysis of the signals. </li></ul><p>Early flow cytometers were generally experimental devices, but recent technological advances have created a considerable market for the instrumentation, as well as the reagents used in analysis, such as <a href="/wiki/Fluorescent_labeling" title="Fluorescent labeling" class="mw-redirect">fluorescently-labeled</a> antibodies and analysis software.</p><p>Modern instruments usually have multiple lasers and fluorescence detectors (the current record for a commercial instrument is 4 lasers and 18 fluorescence detectors). Increasing the number of lasers and detectors allows for multiple antibody labelling, and can more precisely identify a target population by their <a href="/wiki/Phenotype" title="Phenotype">phenotype</a>. Certain instruments can even take digital images of individual cells, allowing for the analysis of fluorescent signal location within or on the surface of cells.</p><p>The data generated by flow-cytometers can be plotted in a single <a href="/wiki/Dimension" title="Dimension">dimension</a>, to produce a <a href="/wiki/Histogram" title="Histogram">histogram</a>, or in two dimensional dot plots or even in three dimensions. The regions on these plots can be sequentially separated, based on fluorescence <a href="/wiki/Intensity" title="Intensity" class="mw-redirect">intensity</a>, by creating a series of subset extractions, termed &quot;gates&quot;. Specific gating protocols exist for diagnostic and clinical purposes especially in relation to <a href="/wiki/Haematology" title="Haematology" class="mw-redirect">haematology</a>. The plots are often made on logarithmic scales. Because different fluorescent dyes' emission spectra overlap <a rel="nofollow" href="http://pingu.salk.edu/flow/fluo.html" title="http://pingu.salk.edu/flow/fluo.html" class="external autonumber">[1]</a>, signals at the detectors have to be compensated electronically as well as computationally.</p><p><a name="Fluorescence-activated_cell_sorting" id="Fluorescence-activated_cell_sorting"></a></p><h2><span class="editsection"></span><span class="mw-headline">Fluorescence-activated cell sorting</span></h2><p>Fluorescence-activated cell sorting (FACS) is a specialised type of flow cytometry. It provides a method for sorting a heterogeneous mixture of biological <a href="/wiki/Cells_%28biology%29" title="Cells (biology)" class="mw-redirect">cells</a> into two or more containers, one cell at a time, based upon the specific <a href="/wiki/Scattering" title="Scattering">light scattering</a> and <a href="/wiki/Fluorescent" title="Fluorescent" class="mw-redirect">fluorescent</a> characteristics of each cell. It is a useful scientific instrument as it provides fast, objective and quantitative recording of fluorescent signals from individual cells as well as physical separation of cells of particular interest. The acronym FACS is <a href="/wiki/Trademark" title="Trademark">trademarked</a> and owned by <a href="/wiki/Becton_Dickinson" title="Becton Dickinson">Becton Dickinson</a><sup id="_ref-0" class="reference"><a href="#_note-0" title="">[1]</a></sup>. While many immunologists use this term frequently for all types of sorting and non-sorting applications, it is not a generic term for flow cytometry. The first cell sorter was invented by Mack Fulwyler in 1965 using the principle of <a href="/w/index.php?title=Coulter_volume&amp;action=edit&amp;redlink=1" title="Coulter volume (page does not exist)" class="new">Coulter volume</a> a relatively difficult technique to use for sorting and one no longer used in modern instruments. The technique was expanded by <a href="/wiki/Leonard_Herzenberg" title="Leonard Herzenberg">Len Herzenberg</a> who was responsible for coining the term FACS. Herzenberg won the <a href="/wiki/Kyoto_Prize" title="Kyoto Prize">Kyoto Prize</a> in 2006 for his work in flow cytometry.</p><p>The cell suspension is entrained in the center of a narrow, rapidly flowing stream of <a href="/wiki/Liquid" title="Liquid">liquid</a>. The flow is arranged so that there is a large separation between cells relative to their <a href="/wiki/Diameter" title="Diameter">diameter</a>. A <a href="/wiki/Oscillation" title="Oscillation">vibrating</a> mechanism causes the stream of cells to break into individual droplets. The system is adjusted so that there is a low probability of more than one cell being in a droplet. Just before the stream breaks into droplets the flow passes through a fluorescence measuring station where the fluorescent character of interest of each cell is measured. An electrical charging ring is placed just at the point where the stream breaks into droplets. A <a href="/wiki/Electric_charge" title="Electric charge">charge</a> is placed on the ring based on the immediately prior fluorescence intensity measurement and the opposite charge is trapped on the droplet as it breaks from the stream. The charged droplets then fall through an <a href="/wiki/Electrostatic_deflection" title="Electrostatic deflection">electrostatic deflection</a> system that diverts droplets into containers based upon their charge. In some systems the charge is applied directly to the stream and the droplet breaking off retains charge of the same sign as the stream. The stream is then returned to neutral after the droplet breaks off.</p><p><a name="Fluorescent_labels" id="Fluorescent_labels"></a></p><h2><span class="editsection"></span><span class="mw-headline">Fluorescent labels</span></h2><p>The fluorescence labels that can be used, will depend on the lamp or laser used to excite the fluorochromes and on the detectors available:<sup id="_ref-1" class="reference"><a href="#_note-1" title="">[2]</a></sup></p><dl><dt>Blue Argon Laser (488 <a href="http://en.wiktionary.org/wiki/nanometer" title="wiktionary:nanometer" class="extiw">nm</a>) </dt></dl><p>This is an air cooled laser and therefore cheaper to set up and run. It is the most commonly available laser on single laser machines.</p><ul> <li>Green (usually labelled FL1): <a href="/wiki/Fluorescein" title="Fluorescein">FITC</a>, <a href="/wiki/Alexa_Fluor" title="Alexa Fluor">Alexa Fluor&reg; 488</a>, <a href="/wiki/Green_fluorescent_protein" title="Green fluorescent protein">GFP</a>, <a href="/wiki/CFSE" title="CFSE">CFSE</a>, <a href="/wiki/CFDA-SE" title="CFDA-SE">CFDA-SE</a>, <a href="/wiki/DyLight_Fluor" title="DyLight Fluor">DyLight 488</a> </li> <li>Orange (usually FL2): <a href="/wiki/Phycoerythrin" title="Phycoerythrin">PE</a> </li> <li>Red channel (usually FL3): <a href="/w/index.php?title=Peridinin_chlorophyll_protein&amp;action=edit&amp;redlink=1" title="Peridinin chlorophyll protein (page does not exist)" class="new">PerCP<font style/a>, <a href="/wiki/Alexa_Fluor" title="Alexa Fluor">PE-Alexa Fluor&reg; 700</a>, <a href="/w/index.php?title=PE-Cy5_%28TRI-COLOR%C2%AE%29&amp;action=edit&amp;redlink=1" title="PE-Cy5 (TRI-COLOR®) (page does not exist)" class="BACKGROUNDnew">PE-Cy5 (TRI-COLOR&reg;)</a>, <a href="/w/index.php?title=PE-Cy5.5&amp;action=edit&amp;redlink=1" title="PE-Cy5.5 (page does not exist)" class="new">PE-Cy5.5</a>, <a href="/wiki/Propidium_iodide" title="Propidium iodide">PI</a> </li> <li>Infra-red (usually FL4; not provided by all FACS machines as standard): <a href="/wiki/Alexa_Fluor" title="Alexa Fluor">PE-Alexa Fluor&reg; 750</a>, <a href="/w/index.php?title=PE-Cy7&amp;action=edit&amp;redlink=1" title="PE-Cy7 (page does not exist)" class="new">PE-Cy7</a> </li></ul><p><br />Red diode laser (635 nm)</p><ul> <li><a href="/wiki/Allophycocyanin" title="Allophycocyanin">APC</a> </li> <li>APC-Cy7 </li></ul><p><a name="Measurable_parameters" id="Measurable_parameters"></a></p><h2><span class="editsection"></span><span class="mw-headline">Measurable parameters</span></h2><p>This list is very long and constantly expanding.</p><ul> <li>volume and <a href="/wiki/Morphology_%28biology%29" title="Morphology (biology)">morphological</a> complexity of cells </li> <li>cell <a href="/wiki/Pigment" title="Pigment">pigments</a> such as <a href="/wiki/Chlorophyll" title="Chlorophyll">chlorophyll</a> or <a href="/wiki/Phycoerythrin" title="Phycoerythrin">phycoerythrin</a> </li> <li><a href="/wiki/DNA" title="DNA">DNA</a> (<a href="/wiki/Cell_cycle" title="Cell cycle">cell cycle</a> analysis, cell <a href="/wiki/Kinetic" title="Kinetic">kinetics</a>, <a href="/wiki/Proliferation" title="Proliferation">proliferation</a> etc.) </li> <li><a href="/wiki/RNA" title="RNA">RNA</a> </li> <li><a href="/wiki/Chromosome" title="Chromosome">chromosome</a> analysis and sorting (library construction, chromosome paint) </li> <li><a href="/wiki/Protein" title="Protein">protein</a> expression and localization </li> <li>transgenic products <em>in vivo</em>, particularly the <a href="/wiki/Green_fluorescent_protein" title="Green fluorescent protein">Green fluorescent protein</a> or related fluorescent proteins </li> <li>cell surface <a href="/wiki/Antigen" title="Antigen">antigens</a> (<a href="/wiki/Cluster_of_differentiation" title="Cluster of differentiation">Cluster of differentiation</a> (CD) markers) </li> <li><a href="/wiki/Intracellular" title="Intracellular">intracellular</a> antigens (various <a href="/wiki/Cytokine" title="Cytokine">cytokines</a>, secondary mediators etc.) </li> <li>nuclear <a href="/wiki/Antigen" title="Antigen">antigens</a> </li> <li><a href="/wiki/Enzyme" title="Enzyme">enzymatic</a> activity </li> <li><a href="/wiki/PH" title="PH">pH</a>, intracellular <a href="/wiki/Ionize" title="Ionize" class="mw-redirect">ionized</a> <a href="/wiki/Calcium" title="Calcium">calcium</a>, <a href="/wiki/Magnesium" title="Magnesium">magnesium</a>, <a href="/wiki/Membrane_potential" title="Membrane potential">membrane potential</a> </li> <li>membrane <a href="/wiki/Fluidity" title="Fluidity" class="mw-redirect">fluidity</a> </li> <li><a href="/wiki/Apoptosis" title="Apoptosis">apoptosis</a> (quantification, measurement of DNA degradation, mitochondrial membrane potential, permeability changes, <a href="/wiki/Caspase" title="Caspase">caspase</a> activity) </li> <li>cell <a href="/wiki/Viability" title="Viability">viability</a> </li> <li>monitoring electropermeabilization of cells </li> <li><a href="/wiki/Oxidative_burst" title="Oxidative burst" class="mw-redirect">oxidative burst</a> </li> <li>characterising <a href="/wiki/Multidrug_resistance" title="Multidrug resistance">multidrug resistance</a> (MDR) in cancer cells </li> <li><a href="/wiki/Glutathione" title="Glutathione">glutathione</a> </li> <li>various combinations (DNA/surface antigens etc.) </li></ul><p><a name="Applications" id="Applications"></a></p><h2><span class="editsection"></span><span class="mw-headline">Applications</span></h2><p>The technology has applications in a number of fields, including <a href="/wiki/Molecular_biology" title="Molecular biology">molecular biology</a>, <a href="/wiki/Pathology" title="Pathology">pathology</a>, <a href="/wiki/Immunology" title="Immunology">immunology</a>, <a href="/wiki/Plant_biology" title="Plant biology" class="mw-redirect">plant biology</a> and <a href="/wiki/Marine_biology" title="Marine biology">marine biology</a>. In the field of molecular biology it is especially useful when used with fluorescence tagged antibodies. These specific antibodies bind to <a href="/wiki/Antigen" title="Antigen">antigens</a> on the target cells and help to give information on specific characteristics of the cells being studied in the cytometer. It has broad application in <a href="/wiki/Medicine" title="Medicine">medicine</a> (especially in transplantation, hematology, tumor immunology and chemotherapy, genetics and sperm sorting in IVF). In marine biology, the auto-fluorescent properties of photosynthetic <a href="/wiki/Plankton" title="Plankton">plankton</a> can be exploited by flow cytometry in order to characterise abundance and community structure. In protein engineering, flow cytometry is used in conjunction with <a href="/wiki/Yeast_display" title="Yeast display">yeast display</a> and <a href="/wiki/Bacterial_display" title="Bacterial display">bacterial display</a> to identify cell surface-displayed protein variants with desired properties.</p><p><a name="See_also" id="See_also"></a></p><h2><span class="editsection"></span><span class="mw-headline">See also</span></h2><ul> <li><a href="/wiki/Fluorescence_microscopy" title="Fluorescence microscopy" class="mw-redirect">Fluorescence microscopy</a> </li></ul><p><a name="Bibliography" id="Bibliography"></a></p><h2><span class="editsection"></span><span class="mw-headline">Bibliography</span></h2><ul> <li>Flow Cytometry First Principles by Alice Longobardi Givan <a href="/wiki/Special:Booksources/0471382248" class="internal">ISBN 0471382248</a> </li> <li>Practical Flow Cytometry by Howard M. Shapiro <a href="/wiki/Special:Booksources/0471411256" class="internal">ISBN 0471411256</a> </li> <li>Flow Cytometry for Biotechnology by Larry A. Sklar <a href="/wiki/Special:Booksources/0195152344" class="internal">ISBN 0195152344</a> </li> <li>Handbook of Flow Cytometry Methods by J. Paul Robinson, et al <a href="/wiki/Special:Booksources/0471596345" class="internal">ISBN 0471596345</a> </li> <li>Current Protocols in Cytometry, Wiley-Liss Pub. ISSN 1934-9297 </li> <li>Flow Cytometry in Clinical Diagnosis, v4, (Carey, McCoy, and Keren, eds), ASCP Press, 2007. ISBN0891895485 </li> <li>Ormerod, M.G. (ed.) (2000) Flow cytometry - A practical approach. 3rd edition. Oxford University Press, Oxford, UK. (<a href="/wiki/Special:Booksources/0199638241" class="internal">ISBN 0-19-963824-1</a>). </li> <li>Ormerod, M.G. (1999) Flow Cytometry. 2nd edition. Bios Scientific Publishers, Ltd. Oxford. IBSN 1 85996 107 X </li></ul><p><a name="References" id="References"></a></p><h2><span class="editsection"></span><span class="mw-headline">References</span></h2><div class="references-small"><ol class="references"> <li id="_note-0"><strong><a href="#ccffcc_ref-0" title="">^</a></strong> <a rel="nofollow" href="http://www.bdbiosciences.com/pdfs/brochures/23-3428-02.pdf" title="http://www.bdbiosciences.com/pdfs/brochures/23-3428-02.pdf" class="external text">FACS MultiSET System</a> (PDF). Becton Dickinson. Retrieved on <a href="/wiki/2007" title="2007">2007</a>-<a href="/wiki/February_9" sizetitle="4February 9">02-09</a>. </li> <li id="_note-1 "><strong><a href="#_ref- color FACS Staining Procedure1" title="">^</a></strong> <cite style="font-style: normal;">Loken MR (1990). &quot;Immunofluorescence Techniques in Flow Cytometry and Sorting&quot;: 341&ndash;53. Wiley.</strongcite><span title="ctx_ver=Z39.88-2004&amp;rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&amp;rft.genre=article&amp;rft.atitle=Immunofluorescence+Techniques+in+Flow+Cytometry+and+Sorting&amp;rft.date=1990&amp;rft.au=Loken+MR&amp;rft.pages=341%26ndash%3B53" class="Z3988"> </span> </li></ol></div><p><a name="External_links" id="External_links"></a></p><h2><span class="editsection"></span><span class="mw-headline">External links</span></h2><ul> <li><a rel="nofollow" href="http://probes.invitrogen.com/resources/education/" title="http://probes.invitrogen.com/resources/education/" class="external text">Tutorials on fluorescence and flow cytometry</a> </li> <li><a href="/wiki/Medical_Subject_Headings" title="Medical Subject Headings">MeSH</a> <em><a rel="nofollow" href="http://www.nlm.nih.gov/cgi/mesh/2007/MB_cgi?mode=&amp;term=Flow+cytometry" title="http://www.nlm.nih.gov/cgi/mesh/2007/MB_cgi?mode=&amp;term=Flow+cytometry" class="external text">Flow+cytometry</a></em> </li> <li><a rel="nofollow" href="http://www.cyto.purdue.edu/flowcyt/educate/pptslide.htm" title="http://www.cyto.purdue.edu/flowcyt/educate/pptslide.htm" class="external text">Powerpoint lectures on flow cytometry</a> </li> <li><a rel="nofollow" href="http://sciencepark.mdanderson.org/fcores/flow/files/Operation.html" title="http://sciencepark.mdanderson.org/fcores/flow/files/Operation.html" class="external text">How a flow cytometer operates</a> </li> <li><a rel="nofollow" href="http://www.fluorophores.org/" title="http://www.fluorophores.org" class="external text">Fluorophores.org - The database of fluorescent dyes</a> </li> <li><a rel="nofollow" href="http://pingu.salk.edu/flow/fluo.html" title="http://pingu.salk.edu/flow/fluo.html" class="external text">Table of fluorochromes</a> </li> <li><a rel="nofollow" href="http://www.bdbiosciences.com/spectra/" title="http://www.bdbiosciences.com/spectra/" class="external text">Java Fluorescence Spectrum Viewer</a> </li> <li><a rel="nofollow" href="http://www.cshprotocols.org/cgi/content/full/2007/22/pdb.prot4895" title="http://www.cshprotocols.org/cgi/content/full/2007/22/pdb.prot4895" class="external text">Combined Flow Cytometric Measurement of Two Cell-Surface</a> </li> <li><a rel="nofollow" href="http://www.cytometry.org/" title="http://www.cytometry.org" class="external text">The Clinical Cytometry Society</a></li><br /ul>
<br />
<br /><font size="2">1. Cell을 FACS buffer에 부유시킴&nbsp;(약 10의 5제곱 cell / 50 ul 정도 되도록 함) 부착세포의 경우에는 trypsin 또는 EDTA 등을 활용하여 부유시킨다. 이때 trypsin 등의 처리에 의해 표적의 표면 분자가 영향을 받는 경우에는 기타 방법을 고려하여야 한다.<br /><br />2. 50 ul을 tube에 분주한다.<br /><br />3. 50 ul의 항체를 첨가한다. 일반적으로 5 ug / ml 의 항체 농도가 되도록 항체를 첨가한다. 그러나, 적용하는 최적의 항체 농도를 결정하기 위해서는 각각의 항체별로 titration을 하여 적정한 항체 농도를 결정하여야 한다.<br /><br />4. 냉장 또는 on ice 상테에서 1시간 배양한다. (경우에 따라서는 30분간 하여도 무방하다.)<br /><br />5. 1ml 의 staining buffer를 첨가하고 부드럽게 mix한다.<br /><br />6. 원심하여 (3000rpm, 5분), 상청액을 제거한다.<br /><br />7. 50 ul의 2nd Ab를 첨가한다. FITC/PE-conjugated (Fab)'2 타동물 유래의 anti-1차 항체 유래 동물의 항체 Ab (세포가 유래된 동물의 Ig으로 absorbed) 를 사용하면 가장 이상적이다. 그러나 일반적으로 Fluorescence-label된 타동물의 항 1차 항체&nbsp; Ab를 사용하며 이 경우에 1차 항체 적용 단계가 끝난 후 (제 6단계후), 2~10% 의 2차 항체 생성동물의 serum을 이용하여 30분 정도 blocking 단계를 추가한다.<br /><br />8. 냉장 또는 on ice 상태에서 1시간 배영한다 (경우에 따라서는 30분간 하여도 무방하다)<br /><br />9. 1ml의 staining buffer를 첨가하고 부드럽게 mix한다.<br /><br />10. 원심하여 (3000rpm, 5분), 상청액을 제거한다.<br /><br />11. 200ul의 staining buffer (PI solution을 첨가한 것 사용) 에 재부유시켜서 즉시 FACS 분석을 실시한다. (PI solution이 세포에 적용된 이후에는 5분 이내에 FACS 분석에 사용하고 늦어도 10분 안에는 FACS 분석을 끝내는 것이 좋다)<br /><br />12. FL3에 양성인 세포는 gate-out 시킨다. (PI에 염색된 세포로 죽은 세포들임)<br /><br /><br /><font style="BACKGROUND-COLOR: #ccffcc" size="4"><strong>Intracellular stain 법<br /><br /></strong><font style="BACKGROUNDbackground-COLORcolor: #ffffff" size="2">위의 protocol을 사용하는데, step 1 후에 다음의 과정을 추가한다.<br />(intracellular stain을 위한 kit를 구입하여 실시하면 더욱 간편하다.)<br /><br />1) Cell을 고정시킨다.<br />&nbsp;- 고정액은, ethanol, acetone, 1% Paraform aldehyde, 1% formalin 등을 사용할 수 있다.<br />&nbsp;- 10분 정도 실온에서 고정한 후에, 충분한 양의 FACS buffer로 wash해 준다.<br /><br />2) 고정된 세포막에 항체가 통과할 수 있는 pore를 만들기 위한 처리를 해준다.<br />&nbsp;- 일반적으로 rgb(0.1% saponin204, 0.5% BSA255, 0.02% NaN3 in PBS) 액을 사용한다 (BSA나 NaN3는 생략가능204)<br />&nbsp;- 실온에서 약 20분 배양한다.<br /><br />3) 위의 protocol에서 step2 이후를 동일하게 실시한다.<br /><br />필요한 시약 및 참고사항<br /><br />-&nbsp;항체 : 항체는 대체로 100~500ug.ml의 농도로 공급되며 필요한 양 만큼만을 따다가 희석해 놓는다. (10X로 희석), 즉 500ug/ml의 원액항체의 경우 300ul의 10X 항체액을 만들 경우, 30ul의 항체원액을 따다가 270ul의 항체 희석액을 섞어서 만든다. (원액항체는 분주하지 않고 보관함.) 희석한 항체는 4도씨에서 보관한다.<br />(새로운 항체를 이용할 때는 항체를 계단 희석하여 가장 최적의 항체농도를 결정한 후에 사용해야 한다. 그러나 일반적으로 1~5ug/ml의 농도가 적당하다)<br /><br />- 항체 희석액 : PBS containing 0.02% sodium azide (NaN3), 0.1% BSA<br /"><br />- FACS buffer : PBS containing 0.01% sodium azide, 2~5% serum (염색하고자 하는 세포가 유래한 동물종의 serum) (serum을 넣는 것은 Fc receptor의 blocking 용이므로 Fc receptor가 없는 세포의 경우에는 안넣어도 됨). high background sample의 경우에 세포가 유래한 동물의 serum을 2~10% 첨가하면 background stain을 낮출 수 있다.<br />참고) Blocking을 위해서 2) 단계 다음에, 항체를 만든 동물의 serum 2~5%를 첨가한 PBS를 100ul 넣어주고 30분간 배양하여 우너심으로 상청액을 제거하고 90ul의 FACS buffer에 재부유시켜 3)의 단계로 진행하기도 한다.<br /><br />Propidium Iodide (PI)<br />- Stock solution으로 0.5 mg/ml로 만들어서 냉동보관 (-20도)<br />- staining buffer에 1/200으로 희석하여 사용<br /><br /><br /></font><br /><strong>[[실험에서 사용한 Protocol]] </strong><br />
</font></font>

Navigation menu